| Fitting Instructions |
|
|
| FireHalt® Downlighter covers have been developed to provide maximum protection for holes created by the introduction of a
downlighter and to allow for ease of fitting. In a fire situation, the cover expands internally to fill all the available space with a fire resistant, highly insulating char. The fire is unable to penetrate the hole and the cover gives additional
insulation protection to the ceiling void by reducing the possibility of heat build up and ignition of flammables, such as accumulated dust and insulation. |
| Step One:
Grasp legs firmly and roll the cover into a cylinder. Ensure the wiring loom is through the slot provide before installation
|
|
 |
|
|
Step Two:
Keeping a tight grip on the legs, feed the cover through the cut out made for the downlighter.
|
|
|
Step Three:
Ensure cover has sprung back into it’s original cone shape.
(a) Grasp legs and pull down until L section clears the underside of the ceiling
(b) Move legs out until vertical part of L section is flush with the side of the cut out |
|
 |
|
|
Step Three:
(a) Release legs so that they grip the underside of the tile.
(b) Remove the excess from both legs, cut at point A.
For double layers of plasterboard or ceilings thicker than 15mm the cut legs can be pushed between sheets or into ceiling tiles or plasterboard |
|